Time Transit Ultrasonic Flowmeter D118

Time Transit Ultrasonic Flowmeter D118
Time Transit Ultrasonic Flowmeter D118
Price And Quantity
  • 1
  • Unit/Units
    Product Description

    Time Transit Ultrasonic Flowmeter D118

    • It is a state-of-the-art transit time ultrasonic flowmeter.
    • Designed using the latest digital technology and low-voltage broadband pulse transmission.
    • While principally designed for full-pipe clean liquid applications.
    • The instrument is tolerant of liquids with small amounts of air bubbles or suspended solids found in most industrial environments.
    • Comparing with other traditional flowmeter or ultrasonic flowmeter, it has distinctive features such as high precision, high reliability, high capability and low cost, other features:
    • TVT technology designed.
    • Less hardware components, low voltage broadband pulse transmission, low consumption power.
    • Clear, user-friendly menu selections make flowmeter simple and convenient to use.
    • Daily, monthly and yearly totalized flow.
    • Parallel operation of positive, negative and net flow totalizes with scale factor (span) and 7 digit display, while the output of totalize pulse and frequency output are transmitted via relay and open collector.

    Specifications

    Flow range

    ±0.03ft/s ~±40ft/s (±0.01m/s~±12m/s)

    Accuracy

    ±0.5% of measured value (for ±1.5ft/s ±40ft/s)

    Repeatability

    0.15% of measured value

    Linearity

    ±0.5%

    Pipe size

    1" to 200"(25mm to 5000mm)

    Function specifications

    Outputs

    Analog output: 4~20mA, max load 750Ω.

    Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable)

    Realy output: SPST, max 1Hz,(1A@125VAC or 2A@30VDC)

    Communication

    RS232&RS485

    SD Card

    Standard SD card

    Max record:512days

    Record time interval

    Power supply

    90 to 245 VAC, 48 to 63 Hz. or 10 to 36VDC

    Keypad

    22 keys with tactile action

    Display

    40 character, 2 line (20X2) lattice alphanumeric, backlit LCD

    Temperature

    Transmitter:- -40~140(-40~ 80)

    Transducer:-40~176(-40~ 80,standard)

    Humidity

    Up to 99% RH, non-condensing

    Physical specifications

    Transmitter

    NEMA 4X (IP65), Die-cast aluminium

    Transducer

    Encapsulated design

    Double-shielded transducer cable

    Standard/maximum cable length:30ft/1000ft (9m/305m)

    Weight

    Transmitter : approximately 2.15kg;

    Transducer : approximately 0.9kg



    Contact Us

    D - 998, First Floor, Palam Extn., Sector-7, New Delhi, Delhi, 110077, India
    Phone :65151223/45613132