Portable UFM for Dirty & Aerated Liquids

Portable UFM for Dirty & Aerated Liquids
Portable UFM for Dirty & Aerated Liquids
Price And Quantity
  • Piece/Pieces
  • 1
  • Piece/Pieces
  • 270000 INR
    Product Description

    Ultrasonic Portable Flow Meter for Dirty & Aerated Liquids

    Features :

    • Troubleshoot Flow from Outside a Pipe
    • Simple-key Calibration 5
    • 300,000 point Data Logger
    • 4-20mA Output
    • 10-Digit Totalizer
    • AC/DC Operation
    • Built-in Rechargeable Battery

    Use a Greyline PDFM 5.1 Portable Doppler Flow Meter to monitor and balance flow, or to troubleshoot flow problems in pipes. It is ideal to full evaluate performance of in-line flow meters and can be installed, calibrated and started-up in minutes. The flow rate of any fluid can be measured as long as it contains air bubbles or solids. It is ideal for wastewater, slurries, sludge, and most chemicals, acids, caustics, and lubrication fluids.

    Recommended for:

    • Sewage
    • Treated Wastewater
    • Aerated Water
    • Sludge And Slurries
    • Chemicals and Solvents
    • Viscous Liquids
    • Abrasives
    • Food Products
    • Pulp Stock
    • Acids and Caustics

    Technical Specifications

    Flow Rate Range

    ± 0.1 to 40ft/sec ( ± 0.03 to 12.2 m/sec)

    Pipe Size

    Ultrasonic Sensor mounts on any pipe from ½" to 180" ID (12.5 mm to 4.5 m)

    Display

    White, backlit matrix - displays flow rate, totalizer, operating mode and calibration menu

    Power Input

    Built-in battery NiMH for up to 18 hours continuous operation

    External charger with 100-240VAC 50/60Hz input

    Outputs

    4-20mA (500 ohm) when AC powered

    USB for Data Log transfer by direct PC connection

    Data Logger

    Programmable 300,000 data point capacity, time and date stamped or formatted flow reports including total, average, minimum, maximum and times of occurrence

    PC Software

    Greyline Logger’ for Windows Vista or higher. Retrieves, displays and saves data log files

    Electronics Operating Temperature

    -10° to 140°F (-23° to 60°C)

    Accuracy

    ±2% of reading or 0.1 ft/sec (0.03 m/sec). Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: ±0.1%, Linearity ±0.5%


    Trade Information
    • 500-1000 Per Month
    • 30 Days
      Contact Us

      D - 998, First Floor, Palam Extn., Sector-7, New Delhi, Delhi, 110077, India
      Phone :+918037302101